F1
GE
Control board or keypad, typically a button reading as permanently held down.
F2
Whirlpool
Over-temperature condition. A probe losing calibration most of the time, occasionally a welded relay.
F3
Maytag
The probe circuit reads open or implausible, and heating stops rather than continue without a figure.
F9
Whirlpool
Door lock motor or latch switch. Nothing heats until the position is confirmed.
E-0
Samsung
Touch panel or control communication fault, which tends to appear after a cleaning cycle.
F19
Bosch
NTC probe or thermal cut-out intervening, with the appliance shutting itself down.
LOC
LG
The catch is either stuck or failing to confirm its state back to the controller.
F7
KitchenAid
Either the film behind the fascia has shorted or one button is permanently depressed.
F14
Miele
The closure sensor will not confirm, so the cycle waits forever.
If the code appeared immediately after a self-clean run, say so on the phone. Hours at cleaning temperature stress the sensor, the locking motor and the controller simultaneously, so we work through them in a different order.